Laboratory Root Cause Analysis
Herguth Laboratories, Inc. provides industry with laboratory root cause analysis. We are ISO 9001:2000 certified and specialize in the analysis of lubricants, fuels, greases and tribological related failures.
Herguth Laboratories, Inc. provides Tribological services as follows:
Wear Analysis
- Determine mechanism of wear and solutions by examination of worn parts
- Analysis of Lubricants
- Wear Particle Analysis
Performance Tests
- " Pin-on-Disk " by ASTM G-99-90
- 4-ball tests by ASTM D-1583, ASTM D-2283 and ASTM D-4172 measure friction and wear of metal/lubricant
combinations under boundary lubrication conditions
- "Pad-on-Disk"
- Friction
- Electrical contact under hydrodynamic conditions
- Ball bearing torque measurements
- Fretting Corrosion tests for metal/lubricant combinations
To satisfy the needs of our clients we have developed Research Associate Program. This program allows experts in many different fields the opportunity to work with Herguth Laboratories, Inc. in their area of expertise as required by specific projects.
Scanning Electron Microscope (SEM) Image

View of the Pin from the Pin-On-Disk Tribometer
Polymer Separation as Point of Contact
The client had excessive “rubber like” deposits forming in a $600,000 gearbox. This happened shortly after changing to a different brand of lubricant. Using SEM and other analysis, Herguth Laboratories, Inc. successfully argued that the polymer was unstable and was the source of the deposit. Our client recouped ALL of their cost associated with this failure!
For more information call 1-888-HERGUTH (437-4884)
|